Violet Freshwater Diversion Project (PO-35)

Client

Arcadis

Dates

May 2009 to February 2010

ENCOS was sub-contracted to Arcadis to design and install 13 hydrographic data collection stations that collected water level and salinity data at mid water depth and 2 meteorological stations in the Violet Freshwater Diversion Project (PO-35) Area.  ENCOS provided monthly servicing of the water level instruments, data download, and calibration, of the water level instruments.  Each water level instrument wass surveyed and the water level data was corrected to North American Vertical Datum 1988 (NAVD 88).  The two weather stations transmitted data real-time on an hourly basis.  Once the data was recovered ENCOS performed QA/QC according to OCPR protocols and provided this data in EXCEL format. 

ENCOS was contracted to perform two synoptic discharge measurements that represented typical summer and winter weather conditions of the project area.  The data collected was for input into a hydrologic model that will assist in the design, planning, and construction of the diversion.

Services Highlighted in Case Study
Data Collection For Hydrologic Model Development Request This Service
Rentals Highlighted in Case Study
In Situ Hydrographic Equipment Aqua Troll 200 Request This Rental
Nexsens iSic 6100 Data Logger Request This Rental
Quake Global Modems Q9612 Iridium Modem Request This Rental

Back
Home | Contract Personnel | Job Seekers | Services | Rentals | Training | Contact | About | ENCOS/Phoenix Job Opportunities
© 2017 ENCOS/Phoenix All Rights Reserved
image 1 image 3 image 4 image 5